  D1U2-W-400-12-HA4C 54mm 1u front end ac-dc power supply converter D1U2-W-400-12-HA4C.a04 page 1 of 6 www.murata-ps.com www.murata-ps.com/support for full details go to www.murata-ps.com/rohs $ ordering guide part number power output high line ac power output low line ac main output standby output air? ow D1U2-W-400-12-HA4C 400w 400w 12v 5v back to front input characteristics parameter conditions min. nom. max. units voltage operating range 90 115/230 264 vac frequency 47 50/60 63 hz turn-on voltage ramp up 85 vac turn-off voltage ramp down 85 maximum current at vin=100vac 400w 5 arms inrush current cold start between 0 to 200msec 30 apk power factor at 230vac, full load 0.99 ef? ciency (100vac) including fan load 35% load 80 % 50% load 85 100% load 85 output voltage characteristics output voltage parameter conditions min. typ. max. units 12v voltage set point 12.0 vdc line and load regulation 11.8 12.2 ripple voltage & noise 1 20mhz bandwidth 120 mv p-p output current (230vac) 0 33.3 a load capacitance 0 15,000 f 5vsb voltage set point 5.0 vdc line and load regulation 4.85 5.15 ripple voltage & noise 1 20mhz bandwidth 50 mv p-p output current 0 3 a load capacitance 0 500 f 1 ripple and noise are measured with 0.1 f of ceramic capacitance and 10 f of tantalum capacitance on each of the power supply outputs. a short coaxial cable with 50 scope termination is used. features ? 400w output power ? 12v main output ? 5v standby output of 15w ? 1u height: 2.15"x13.67"x1.58" ? 8.6 watts per cubic inch density ? ef? ciency 85% at full load, 100vac and 50c ? n+1 redundancy capable, including hot plugging (up to 4 in parallel) ? active current sharing on 12v main output, oring fet ? overvoltage, overcurrent, overtemperature protection ? internal cooling fan (variable speed) ? psmi and smbus / i2c interface with bicolor led status indicators ? rohs compliant product overview the D1U2-W-400-12-HA4C is a 400 watt, power factor corrected front end supply with a 12v main output and a 5v (15w) standby. it features active current sharing and up to 4 supplies maybe operated in parallel. the supply may be hot plugged, it recovers from overtemperature faults, and has status leds on the front panel in addition to logic and psmi status signals. the supply comes in a low pro? le 1u package and has >8w/cubic inch power density, making it ideal for delivering reliable, ef? cient power to servers, workstations, storage systems and other 12v distributed power systems. cb test certi cate and test report www.murata-ps.com / en / 3d / acdc.htm l www.murata-ps.com / en / 3d / acdc.htm l www.murata- p s.com/en/3d/acdc.htm l www.murata-ps.com / en / 3d / acdc.htm l www.murata- p s.com/en/3d/acdc.htm l www.murata-ps.com / en / 3d / acdc.htm l available now at www.murata-ps.com/en/3d/acdc.html
D1U2-W-400-12-HA4C 54mm 1u front end ac-dc power supply converter D1U2-W-400-12-HA4C.a04 page 2 of 6 www.murata-ps.com/support output characteristics parameter conditions min. typ. max. units output rise monotonicity no voltage excursion startup time ac ramp up 1.5 2.0 s transient response 12v, 30-70% load step, 1a/s di/dt 3 % 5vsb, 30-70% load step, 0.1a/s di/dt 3 current sharing accuracy (up to 4 in parallel) at 100% load 10 hot swap transients all outputs within regulation holdup time 20 ms environmental characteristics parameter conditions min. typ. max. units storage temperature range -40 70 c operating temperature range 050 operating humidity noncondensing 5 90 % storage humidity 595 altitude (without derating at 55c) 3,000 m shock 30g non operating operational vibration 0.5g, 5 C 500 hz mtbf per telcordia sr332m1c1 @25c 300k hrs safety approvals csa/ul 60950-1-07-2nd ed. iec 60950-1:2005 (2nd edition) w am. 1:2009 en 60950-1:2006 +a11:2009 +a1:2010 ce marking per lvd directive 2006/95/ec input fuse power supply has internal 10a/250v fast blow fuse on the ac line input switching frequency 90khz for boost pfc converter 200khz for main output converter weight 2.28lbs (1.034kg) protection characteristics output voltage parameter conditions min. typ. max. units overtemperature (intake) autorestart 65 70 75 c 12v overvoltage latching 14.0 14.5 v overcurrent hiccup 115 130 % 5vsb overvoltage latching 5.7 5.9 v overcurrent autorecovery 4.4 6.0 a isolation characteristics parameter conditions min. typ. max. units insulation safety rating / test voltage input to output - reinforced 3000 vrms input to chassis - basic 1500 vrms isolation output to chassis 500 vrms control signals condition led status standby - on; main output - off; ac present blinking green standby - on; main output - on solid green main/standby output overcurrent, undervoltage, overvoltage warning blinking yellow fan_fault; overtemperature; main/standby output overcurrent, undervoltage, overvoltage fault yellow
D1U2-W-400-12-HA4C 54mm 1u front end ac-dc power supply converter D1U2-W-400-12-HA4C.a04 page 3 of 6 www.murata-ps.com/support emissions and immunity characteristic standard compliance input current harmonics iec/en 61000-3-2 complies voltage fluctuation and flicker iec/en 61000-3-3 complies conducted emissions fcc 47 cfr part 15/cispr 22/en55022 class b esd immunity iec/en 61000-4-2 level 3 criteria a radiated field immunity iec/en 61000-4-3 level 3 criteria b electrical fast transients/burst immunity iec/en 61000-4-4 level 3 criteria a surge immunity iec/en 61000-4-5 level 3 criteria a radiated field conducted immunity iec/en 61000-4-6 level 3 criteria a magnetic field immunity iec/en 61000-4-8 3 a/m criteria b voltage dips, interruptions iec/en 61000-4-11 230vin, 100% load, phase 0, dip 100% duration 10ms (a) 230vin, 50% load, phase 0, dip 100% duration 20ms (vsb:a, v1:a) 230vin, 100% load, phase 0, dip 100% duration > 20ms (vsb, v1:b) dc output connector and signals the dc output connector is a tyco minipak hdl connector tyco p/n: 1926734-1 . mating pin sequencing shall be 12v_rtn ? rst, 12v second, signals third and pskill_l signal last. pskill_l is the last to mate and ? rst to break and is used as a power supply output enable for the 12v rail. mating part: tyco p/n 1-1926739-8 power supply output connector isometric and front views front connector view looking at blades and pins (view looking in at rear of power supply)
D1U2-W-400-12-HA4C 54mm 1u front end ac-dc power supply converter D1U2-W-400-12-HA4C.a04 page 4 of 6 www.murata-ps.com/support dc output connector and signals (continued) power supply output connector power blade and signal pin allocation power blade number signal function signal direction blade sequencing p1, p2, p3, p4 rtn 12v return output level 3 upm pwr p5, p6, p7, p8 12v 12v output output level 2 upm pwr a1 smb_alert_l i2c serial bus interrupt output level 2 signal a2 pson_l power supply on input a3 pskill_l power supply enable input level 1 signal a4, a5 5vsb 5v standby voltage output level 2 signal b1 smb_scl i2c serial bus clock bi-directional level 2 signal b2, b3 rtn ground output b4, b5 5vsb 5v standby voltage c1 smb_sda i2c serial bus data / address bi-directional level 2 signal c2, c3, c4, c5 rtn ground output d1 smb_a1 i2c serial bus address bit a1 input level 2 signal d2 rtn ground output d3 12ls 12v current share line bi-directional d4 12v_rs- 12v remote sense negative input d5 12v_rs+ 12v remote sense positive e1 smb_a0 i2c serial bus address bit a0 input level 2 signal e2 rtn ground output e3 pwok_h power ok status bit e4 ff1_h fan fail #1 status output e5 ff2_h fan fail #2 status output view into mating face of 25s8p minipak hdl plug signal contacts: choice of level 1 (l1) or level 2 (l2) power contacts: choice of level 2 (l2) or level 3 (l3) column: row: e d c b a 1234512345678
D1U2-W-400-12-HA4C 54mm 1u front end ac-dc power supply converter D1U2-W-400-12-HA4C.a04 page 5 of 6 www.murata-ps.com/support wiring diagram current sharing notes 12v output: current sharing is achieved using the active current share method. (see wiring diagram section for connection deta ils.) the total combined load must be below 400w at startup. startup of parallel power supplies is not internally synchronized. it is recommended that the paralleled pow er supplies be turned on at the same time (with their pson_l signals). current sharing can be achieved with or without remote sense connected to the common load. 5vsb output: 5vsb outputs can be tied together for redundancy but total combined output power must not exceed 15w. the 5vsb o utput has internal oring mosfet for additional redundancy / internal short protection. up to four units can be paralleled together. outputs of ac input units (d1u2-w-400) and dc input units (d1u2-d-400) can be par alleled together. please consult your murata sales representative if operation with more than four units in parallel is needed. dc out return +remote sense -remote sense +dc out d5 p5-p8 p1-p4 d4 - dotted lines show optional remote sense connections. optional remote sense lines can be attached to a load that is a distance away from the power supply to improve regulation at the load. d1u2 12v load a2 b2, b3, c2-c5, d2, e2, e5 a4, a5, b4, b5 close switch (or fet, bjt, or wire) to turn on +dc out +5v logic circuitry 5vsb pson_l rtn a3 pskill_l d1u2 d5 p5-p8 p1-p4 d4 a4, a5, b4, b5 a2 b2, b3, c2-c5, d2, e2, e5 a3 pson_l pskill_l d3 12ls d3 rtn +dc out dc out return -remote sense 12ls 5vsb +remote sense
D1U2-W-400-12-HA4C 54mm 1u front end ac-dc power supply converter D1U2-W-400-12-HA4C.a04 page 6 of 6 www.murata-ps.com/support murata power solutions, inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. the descriptions contained her ein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. speci? cations are subject to cha nge without notice. ? 2013 murata power solutions, inc. murata power solutions, inc. 11 cabot boulevard, mans? eld, ma 02048-1151 u.s.a. iso 9001 and 14001 registered this product is subject to the following operating requirements and the life and safety critical application sales policy: refer to: http://www.murata-ps.com/requirements/ mechanical dimensions dimensions: 2.15" x 13.67" x 1.58" [54.5mm x 347.2mm x 40.2mm] optional accessories description part number 12v d1u2 output connector card d1u2-12-conc application notes document number description tbd d1u2 output connector card tbd d1u2 communication protocol ac input connector: iec 320-c14 9.41 0.35 0.370 0.014 8.15 0.35 0.321 0.014 matting surface of signal pins field 40.20 0.50 1.583 0.020 [1] 39.00 0.50 1.535 0.020 [1] 26.16 1.00 1.030 0.039 [1] 66.55 0.50 2.620 0.020 [1] 347.20 0.50 13.669 0.020 [1] 380.20 ref 14.969 33.00 ref 1.299 54.50 0.50 2.146 0.020 [1] 340.40 0.50 13.402 0.020 [1] matting surface of signal pins field air? ow back to front


▲Up To Search▲   

 
Price & Availability of D1U2-W-400-12-HA4C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X